FX5000-MM - FIBERXPERT OTDR 5000 Fibre Optic Fibre Cabling Certifier

FiberExpert SKU: FX5000-MM

$20,610.19 NZD

Shipping calculated at checkout

Currently out of stock - please call us

FIBERXPERT OTDR 5000 Fibre Optic Fibre Cabling Certifier. Measures Multimode Only 850/1300nm Optical Time Domain Reflectometer. *Bought in to Order - 14 Day Lead

Designed with the installers and operators of enterprise networks in mind, the FiberXpert OTDR 5000 measures, documents and troubleshoots fibre optic networks. The FiberXpert OTDR 5000 provides very high resolution with one of the shortest dead zones available for testing multimode fibres, thus enabling measurement of very short fibre links. Automatic analysis features simplify the measurement tasks.

Features:

  • Optical Time Domain Reflectometer (OTDR) for 850/1300nm Multimode
  • Standards compliant Tier 2 measurement of fibre optic cabling
  • Automatic Pass/Fail analysis of the test results according to the limits specified by TIA/IEC
  • Display of the OTDR trace in a graphical format for a length-dependent analysis of all events for reflection and attenuation
  • All fibre link events and analysis listed in a table of results
  • Automatic macro-bend detection
  • No need to understand graphical OTDR traces any more thanks to icon-based SmartLink
  • Built-in optical loss test set
  • Optional fibre inspection probe
  • Large colour LCD touch screen
  • Generation of professional reports with the central eXport evaluation software
    General (Typical at 25°C)  
    Weight  1.26kg
    Dimensions (w × h × d) 128 x 134 x 40mm
    Optical Interfaces  
    Interchangeable optical connectors FC, SC, DIN, and ST
    Technical Characteristics  
    Laser safety class (21 CFR) Class 1
    Distance units  Kilometers, feet, and miles
    Group index range  Up to 128,000 data points
    Number of data points Up to 128,000 data points
    Distance measurement Automatic or dual cursor
    Display range  3.25m to 260km
    Cursor resolution  1cm
    Sampling resolution  4cm
    Accuracy  ± 1m ± 10-5 x distance, ± sampling resolution, (Excluding group index uncertainties)
    Attenuation Measurement  
    Automatic, manual, 2-point, 5-point, and LSA  
    Display range 1.25dB to 55dB
    Display resolution 0.001dB
    Cursor resolution 0.001dB
    Linearity ±0.03dB/dB
    Threshold  0.01 to 5.99dB in 0.01dB steps
    Reflectance/ORL Measurements  
    Reflectance accuracy  ±2dB
    Display resolution  0.01dB
    Threshold  11 to −99dB in 1dB steps
    CW Source  
    CW Source output power level  −3.5dBm
    Operating modes  CW, 270Hz, 330Hz, 1kHz, 2kHz, TWINTest
    Power Meter  
    Power level range  MM: −3 to −30dBm, SM: −2 to −50dBm
    Calibrated wavelengths MM: 850 and 1300nm, SM: 1310, 1490, 1550, 1625, and 1650nm
    Measurement accuracy  MM1: ±1dB (At -15dBm), SM: ±0.5dB (At -30dBm) 
    Multimode and Quad OTDR Modules (Typical at 25°C)  
    Central wavelength 850/1300 ±30nm, 1310/1550 ±20nm
    Pulse width  3ns to 1μs, 3ns to 20μs
    RMS dynamic range 26/24dB, 37/35dB
    Event dead zone 0.8m, 0.9m
    Attenuation dead zone 4m, 4m